Type of Product |
Medical Device |
TGA Recall Reference |
RC-2016-RN-00188-1 |
Product Name/Description |
iMDsoft MetaVision ICU (MV-ICU), Version 5.47.4622 (graphical patient information system used for data collection, management, and storage)
ARTG Number: 165518 |
Recall Action Level |
Hospital |
Recall Action Classification |
Class III |
Recall Action Commencement Date |
22/02/2016 |
Responsible Entity |
|
Reason/Issue |
A software issue has been identified in the medication management module which may lead to duplication of medication dose under specific settings. This can only occur when a medication order has a weekly interval (e.g., administer medication X every Monday) and an attribute (e.g, dose quantity or frequency) of the order is subsequently modified. |
Recall Action |
Recall for Product Correction |
Recall Action Instructions |
A temporary mitigation was provided by means of modifying the software configuration setting. Specifically, the proposal was to extend the time horizon from 7 days, which is equal to the dose interval, to greater than 7 days. A permanent solution will be provided once it becomes available. |