| TGA Action ID |
RC-2026-RN-00822-1 |
| Type of Product |
Medicine |
| Product Name/Description |
Ifosfamide 2,850mg, Mesna 4,770mg in 0.9% Sodium Chloride in Polyolefin Bag (Freeflex) for Intravenous Infusion
Batch Number: BB26103194
Expiry Date: 13/10/2026
ARTG Exempt |
| ARTG Number |
|
| Unique Device Identifier (UDI) |
BB26103194 |
| Action Type |
Recall |
| Action Level |
Hospital |
| Hazard Classification |
Class II |
| Reason for the Action |
Prior to patient treatment, the treating clinician assessed that the product supplied did not meet the dose requirements of the order that was placed with Slade Health.
Ordered: Mesna 2850mg, Ifosfamide 4770mg Label Claim and Supplied: Ifosfamide 2850mg, Mesna 4770mg
Given the nature of the product, this action was undertaken prior to TGA notification (Immediate Market Action as defined within the PRAC). |
| Instructions for Customers/Users |
Product was discarded by treating clinican prior to use. Customer did not require a replacement product. |
| Action Commencement Date |
15/10/2026 |
| Responsible Entity |
|
| Contact Information |
03 9565 4300 - Slade Health Head Office |